Optimized hydraulic diameter and operating condition of tube heat exchanger for food industry – A numerical study

Closed

I. Made Arsana, Yopi Ramadhani Robi Putra, Handini Novita Sari, Ika Nurjannah, Ruri Agung Wahyuono

2020 Journal of Mechanical Engineering Research and Developments Vol. 43 Issue 6 Article Cited by 2 Quartile

Abstract

This work reports the design optimization of a tube heat exchanger, which is widely employed and integrated in the stove system in small scale food processing industry in Indonesia. The optimization parameters were the tube diameter and the flow rate of working fluids, which are later corelated to the heat exchanger effectiveness (ε). Numerical investigation using Computational Fluid Dynamics (CFD) with viscous model of kε RNG was undertaken to obtain the optimum parameter. The tube diameter was varied by 0.5, 1, and 1.5 in while the flow rate was varied by using initial inlet velocity of 1.6, 3.6, and 5.6 m‧s-1. The results indicate that the highest ε of 1.36 can be achieved using 0.5 in tube diameter with the slowest inlet velocity (1.6 m‧s-1). This result is manifested by the higher temperature difference between the outflow and inflow, and the considerably low pressure drop amongst all variation. Therefore, this study recommends the current food processing industry to redesign the existing tube heat exchanger in order to increase the production efficiency. © 2020 Zibeline International Publishing Sdn. Bhd.. All rights reserved.

Affiliations

Department of Mechanical Engineering, Universitas Negeri Surabaya, Surabaya, 60231, Indonesia; Department of Engineering Physics, Institut Teknologi Sepuluh Nopember, Surabaya, 60111, Indonesia